Everything else in formation evaluation is calibrated against this page. Logs read the rock from the borehole wall; core and laboratory work read the rock itself. The difference between what a log infers and what a plug measures is where most petrophysical uncertainty lives.
← Back to the catalogue · Part 02 of 04 · 18 methods
2.1 Borehole petrophysical methods
Wireline and logging-while-drilling measurements are the most versatile tools in the business: continuous, relatively cheap per metre, and repeatable. They are also indirect — every one of them is an inference from a physical response, calibrated against core somewhere else.
| Method | What it measures | Scale / radius of investigation | How we use the data | Principal limitations |
|---|---|---|---|---|
| Mud logging and gas analysis | Lithology of cuttings, rate of penetration, gas shows and composition | Around the bit, a few metres | First-pass lithology and reservoir-quality indication; early hazard identification | Lag and contamination; depth control |
| LWD / MWD | Gamma ray, resistivity, density–neutron and annular pressure while drilling | As per the equivalent wireline tool | Geosteering; early formation evaluation before pipe is run; wellbore stability monitoring | Tool availability and cost; reduced quality versus wireline |
| Gamma ray and spectral gamma ray | Shale volume, clay type, organic content, radioactive mineralogy | ~20–30 cm vertically; centimetres into the formation | Net-to-gross, clay typing, seal quality, correlation between wells | No porosity information; radioactive heavy minerals mislead |
| Spontaneous potential and resistivity (induction, laterolog) | Formation water resistivity, water saturation, fluid contacts, moveable fluids | Metres to several metres into the formation | Saturation and contact interpretation; salinity estimates; monitoring saturation change | Requires reliable Rw and Archie parameters; thin beds and anisotropy distort results |
| Density–neutron porosity | Total and effective porosity, lithology, gas effect | ~20–30 cm vertically; centimetres into formation | Porosity for volumetrics; gas identification; lithology cross-plots | Shale and gas effects; must be core-calibrated |
| Sonic (monopole, dipole, Stoneley) | Porosity, compressional and shear velocities, elastic moduli, anisotropy, fracture indicators | ~20 cm to a metre; Stoneley senses a few metres | Geomechanical model; rock strength; stress and fracture orientation; synthetic seismogram | Requires calibration; anisotropy interpretation is ambiguous |
| Nuclear magnetic resonance (NMR) | Free and bound fluid volume, effective porosity, pore-size distribution, permeability estimate | Centimetres to a metre | Irreducible water saturation, permeability proxies, fluid typing, calibration to SCAL | Sensitive to acquisition parameters; gas and mud-filtrate effects |
| Borehole image logs (FMI, OBMI, CMI) | Fractures, bedding, faults, breakouts, vugs, dissolution features, with orientation | Centimetre resolution on the borehole wall | Fracture density and orientation, in-situ stress direction, net-to-gross at fine scale, seal continuity | Only the borehole wall; needs core and seismic calibration |
| Elemental spectroscopy (ECS) and mineralogy logs | Elemental composition and derived mineralogy | Centimetres | Mineral model, brittleness indices, clay typing, seal mineralogy | Transform from elements to minerals is non-unique |
| Wireline formation testing (RFT, MDT, DFT) | Pore pressure, pressure gradients, contacts, fluid mobility, in-situ samples, mini-DST, stress tests | Centimetres to tens of metres from the wellbore | Pressure regime, compartmentalisation, connectivity, fluid composition, stress magnitudes | Slow in tight rock; contamination; supercharging in low-permeability zones |
| Downhole fluid analysis and sampling | Brine and hydrocarbon composition, gas content, contaminants, PVT properties, asphaltene onset | Centimetres around the probe | Fluid model; corrosion and scaling assessment; miscibility and phase behaviour | Separating true formation fluid from mud filtrate is difficult; samples are points, not averages |
2.2 Coring and laboratory rock analysis
Core is the only direct sample of the reservoir you will ever hold. It is also a centimetre-scale sample of a kilometre-scale problem, which is why the results are used to calibrate and constrain, never to substitute.
| Method | What it measures | Scale / radius of investigation | How we use the data | Principal limitations |
|---|---|---|---|---|
| Conventional and sidewall coring | Lithology, sedimentary structures, fractures and stylolites at core scale; material for all subsequent tests | Centimetres to tens of metres of section | Direct observation and log calibration; the only way to see fractures and fine-scale heterogeneity | Cost and time; mud invasion alters wettability; core recovery is often biased |
| Routine core analysis (RCA) | Helium porosity, Klinkenberg-corrected permeability, grain density, as-received saturations | Centimetre plugs | Porosity–permeability transforms, net-pay cut-offs, log calibration | Plug-scale; biased to intact rock; vertical permeability rarely measured |
| Special core analysis (SCAL) | Relative permeability curves, capillary pressure, wettability, residual and trapped saturations | Centimetre plugs, tens of centimetres of flow length | Flow functions for simulation; trapped CO2 saturation; sweep efficiency; residual oil for EOR | Slow and expensive; few samples; upscaling to grid blocks is non-trivial |
| Mercury injection capillary pressure (MICP) | Pore-throat size distribution, displacement and entry pressure, seal capacity | Millimetres to centimetres | Quantifies seal capacity and the maximum supportable CO2 column height | Mercury is not brine; requires conversion; small samples may miss defects |
| Petrography, XRD, SEM/EDS, CT scanning | Mineralogy, texture, diagenesis, micro-fractures, pore network geometry, 3D fabric | Microns to centimetres | Explains permeability controls, reactivity, fines migration and seal mineralogy | Local; the scale gap to reservoir models must be bridged explicitly |
| Geomechanical rock testing | UCS, triaxial strength, static and dynamic elastic moduli, Poisson ratio, tensile strength, creep, hardness and ductility indices | Centimetre plugs | Wellbore stability, fracture gradient, cap rock ductility, sanding prediction, fault reactivation analysis | Few samples; static–dynamic discrepancy; in-situ stress must come from elsewhere |
| Rock–fluid reactivity testing | Mineral dissolution and precipitation, permeability change, CO2 trapping mechanisms, cement degradation | Centimetre cores; weeks to months | Long-term injectivity and containment prediction; wellbore material selection | Accelerated and site-specific; scaling time and spatial effects is difficult |
The scale gap is the whole problem
A core plug is a few cubic centimetres. A simulation grid block is often a quarter of a cubic kilometre. Moving relative permeability, capillary pressure and permeability from one to the other — upscaling — involves assumptions about bedding, capillarity and heterogeneity that must be tested against multi-scale data. Do it from one well and the model becomes internally consistent and externally wrong. MICP is also the measurement behind our cap rock framework, which is where centimetre-scale samples decide kilometre-scale containment.