Well & Reservoir Testing

The only measurements that integrate the rock over a volume big enough to matter for flow.

A well test is the one measurement that reports in the units the project is paid in: rate, pressure, time and connected volume. It is also the measurement most often mistaken for a reservoir study — which is the argument behind One Well Is Not a Reservoir. Used properly, it is indispensable. Used as a verdict, it is a liability.

← Back to the catalogue · Part 03 of 04 · 9 methods

What these methods answer

Well tests answer deliverability, connectivity and pressure. They are the only methods that let the rock respond over hundreds of metres and, with long shut-ins and multiple wells, over kilometres. That is why they detect boundaries, baffles and compartments that no log can see — and why they are still blind to whatever lies past their radius of investigation.

MethodWhat it measuresScale / radius of investigationHow we use the dataPrincipal limitations
Drill stem test (DST)kh, skin, productivity or injectivity index, static pressure, representative fluid samplesTens to hundreds of metresThe strongest single-point statement on deliverability and formation damageCostly; flaring and HSE exposure; commingled zones; one location only
Wireline formation testing / mini-DSTZone-by-zone mobility and kh, pressure, fluid samples, stress estimatesMetres to tens of metresRanks layers by productivity; identifies barriers between zones; cheap early dataVery small volume; problematic in tight rock; supercharging
Pressure transient analysis (build-up, drawdown, fall-off)kh, skin, wellbore storage, boundary and fault distance, dual-porosity behaviour, connected volumeHundreds of metres to a few kilometres with long shut-insDetects boundaries and baffles; estimates connected volume; informs well spacingRequires shut-in time and clean data; non-uniqueness of interpretation models
Injection and fall-off testingInjectivity index, effective permeability to the injected phase, closure pressureTens to hundreds of metresThe direct answer to "can this well accept CO2 or water?"Injected fluid differs from formation fluid; near-wellbore effects dominate
Step-rate and injectivity profiling (spinner, DTS/DAS)Fracture opening pressure, zonal injection allocation, conformanceMetres around the wellboreKeeps injection below the fracture gradient; confirms which intervals are taking fluidShort-lived; near-wellbore only
DFIT, minifrac and leak-off testsMinimum horizontal stress, closure pressure, pore pressure, permeability, fracture complexityTens to hundreds of metresDefines the pressure envelope; calibrates the geomechanical model; fracture designModel-dependent interpretation; small injected volumes
Interference, pulse and multi-well testingInter-well connectivity, transmissibility, anisotropy, storativityHundreds of metres to kilometresTests compartmentalisation directly; verifies whether pressure support will reach a producer or a boundaryExpensive; needs multiple wells and long duration
Tracer testing (gas and water phases)Inter-well flow paths, swept volume, fracture fast paths, retention behaviourHundreds of metres to kilometresMaps migration pathways and sweep; identifies thief zones and channelingLong duration; dilution and analysis uncertainty
Cased-hole saturation and production loggingSaturation change behind casing, zonal flow contribution, cross-flow, channelingCentimetres to metres from the wellboreConformance monitoring; verifies plume movement at the well; detects behind-casing flowRequires well access; interpretation in three-phase flow is difficult

The radius-of-investigation arithmetic

A conventional well test with a 300 m radius of investigation, across 100 m of net pay, senses roughly 0.028 km³ of rock. A modest 10 km × 10 km × 100 m reservoir is 10 km³. The test has interrogated about **0.3% of the system** — and it interrogated the part of it that the drilling engineer deliberately chose as the best available rock.

Induced seismicity, cap rock integrity, inter-well interference, spill risk and the area of review all live in the other 99.7%. That is not a criticism of well testing. It is a statement about what a test is for.

What this family cannot tell you

A well test cannot tell you whether the interval is present a kilometre away, whether the seal holds across the area of review, where the plume will migrate, or how many wells the project needs. It can detect a boundary if the test is long enough and the boundary is close enough — and it cannot map the barriers it never reaches. Those questions belong to reservoir description.